Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
J. bras. patol. med. lab ; 44(4): 263-269, ago. 2008. ilus, tab
Article in Portuguese | LILACS | ID: lil-504207

ABSTRACT

OBJETIVOS: Verificar evidências da formação de aerossóis durante a manipulação de cepas de micobactérias para teste de sensibilidade às drogas (ANT) e identificação (TIP) e o efeito da descontaminação com solução de álcool 70 por cento e luz ultravioleta (UV) na cabine de segurança biológica (CSB), após os procedimentos laboratoriais. MÉTODOS: Uma placa foi exposta na CSB durante os procedimentos de ANT e TIP. Ao término, a CSB foi limpa e descontaminada com álcool 70 por cento e exposta à luz UV por 15 minutos. Após esse tempo outra placa foi exposta por duas horas, somente com a ventilação da CSB ligada. As placas foram incubadas a 37ºC e observadas por 30 dias. Os esfregaços das colônias isoladas foram corados pelas técnicas de Ziehl Neelsen e Gram, e as colônias de bacilo álcool-ácido-resistente (BAAR) foram identificadas pelos métodos tradicionais. RESULTADOS: Nas 38 placas expostas durante o ANT, cresceram micobactérias em 10 placas (26,3 por cento), fungos em uma (2,6 por cento) e outros bacilos em duas (5,3 por cento). Das placas com micobactérias, oito (80 por cento) foram identificadas como M. tuberculosis e duas (20 por cento) tiveram identificação inconclusiva. Mesmo após a descontaminação com álcool 70 por cento e uso de UV, cresceram fungos em duas placas (5,3 por cento) e cocos em outras duas (5,3 por cento). Nas 30 placas colocadas nas CSB durante a TIP, cresceram micobactérias em 10 placas (33,3 por cento), fungos em duas (6,6 por cento), cocos em uma (3,4 por cento) e uma mistura de micobactérias e outro bacilo em uma (3,4 por cento). Não houve crescimento nas placas expostas após descontaminação das CSB com álcool a 70 por cento e uso de UV ao término da TIP. CONCLUSÃO: Durante os procedimentos houve formação de aerossóis contendo micobactérias, fato que ficou comprovado pelo crescimento de colônias de micobactérias nas placas expostas. Técnicas laboratoriais adequadas devem ser respeitadas para minimizar a formação de aerossóis...


OBJECTIVES: To verify the evidence of aerosol formation during the manipulation of mycobacteria strains for susceptibility (ST) and identification tests (IT) as well as the decontamination effect of alcohol solution 70 percent and ultraviolet (UV) radiation in biological safety cabinets (BSC) after laboratory procedures. METHODS: One plate was exposed in a BSC during ST and IT procedures. Afterwards, the BSC was cleaned and decontaminated with alcohol solution 70 percent and exposed to UV radiation for 15 minutes. After that, another plate was exposed for two hours, only with the BSC ventilation on. Both plates were incubated at 37ºC and observed for 30 days. The smears from the isolated colonies were stained with Ziehl Neelsen and Gram techniques, and acid fast bacilli (AFB) were identified by conventional methods. RESULTS: In 38 plates exposed during ST, there was mycobacteria growth in 10 plates (26.3 percent), fungi in one (2.6 percent) and bacilli in two (5.3 percent). Among those plates that presented mycobacteria growth, eight (80 percent) were identified as M. tuberculosis and two (20 percent) had inconclusive identification. Even after decontamination with alcohol solution 70 percent and UV radiation, two plates presented fungi growth (5.3 percent) and other two presented cocci growth (5.3 percent). Among 30 plates exposed during IT procedures, there was mycobacteria growth in 10 of them (33.3 percent), fungi in two (6.6 percent), cocci in one (3.4 percent) and one (3.4 percent) mixed mycobacteria and another bacillus. No growth was observed when alcohol solution 70 percent and UV radiation were used for decontamination after IT procedures. CONCLUSION: During the procedures there was aerosol formation with mycobacteria, which was proved by mycobacteria growth on the exposed plates. Not only should adequate laboratory techniques be respected to minimize aerosol formation, but professional expertise, the continuity of capacity...


Subject(s)
Containment of Biohazards , Decontamination/methods , Laboratory Equipment , Aerosols , /prevention & control , Mycobacterium , Ultraviolet Rays
2.
Rev. Inst. Adolfo Lutz ; 65(3): 222-224, set.-dez. 2006. ilus
Article in Portuguese | LILACS, SES-SP, SESSP-CTDPROD, SES-SP, SESSP-IALPROD, SES-SP | ID: lil-461282

ABSTRACT

A cabine de segurança biológica (CSB) é o principal equipamento para efetuar a contenção de aerossóis produzidos nos procedimentos laboratoriais e a descontaminação com lâmpada UV, 15 minutos antes do início das atividades e 15 minutos após utilização da cabine é parte das boas práticas de laboratório. O objetivo deste estudo foi avaliar a ação da lâmpada UV da CSB classe II B2, em diversas espécies de micobactérias e correlacionar com o tempo de exposição. Cepas de referência foram subcultivadas, semeadas e incubadas a 37ºC até produzir turvação compatível com o tubo 1 da escala de MacFarland. Foram semeados 100L de suspensão bacteriana em placas com meio 7H11; as placas foram cobertas parcialmente com papel alumínio e expostas à radiação UV durante 5 e 10 minutos. Após exposição, os papéis foram retirados e as placas incubadas a 37ºC por 30 dias. Todas as placas apresentaram inibição de crescimento de bactérias na porção da placa em que houve exposição direta à radiação UV. Os resultados obtidos mostraram que a prática de utilização da radiação UV por 15 minutos após o uso da cabine e antes de iniciar outra atividade técnica, garante descontaminação adequada da CSB. Esta prática de biossegurança é recomendável para descontaminar a própria CSB e os materiais que são retirados da cabine.


Subject(s)
Biological Contamination , Nontuberculous Mycobacteria , Ultraviolet Rays
SELECTION OF CITATIONS
SEARCH DETAIL